How to equip the air duct for industrial air cooler with an air volume of 18,000?

According to the air volume, we can divide the industrial air cooler with air volumes of 18,000, 20,000, 25,000, 30,000, 50,000 or even larger. If we divide it by the type of main unit, we can divide it into two types: mobile units and industrial units. The mobile unit is very simple. You can use it as long as you connect water and electricity after buying it. However, the industrial air cooler is different. It needs to do the corresponding supporting air duct project to cover every area that needs to be cooled. How should the supporting air duct project of industrial air cooler with an air volume of 18,000 be matched!

18下

Parameters of 18000 air volume industrial air cooler equipment:

The maximum air volume of the 18000 air volume air cooler is: 18000m3/h, the maximum wind pressure is: 194Pa, ​​the output power is 1.1Kw, the voltage frequency is 220/50 (V/Hz), the rated current is: 2.6A, the fan type is: axial flow, the motor type is: three-phase single speed, the operating noise is: ≤69 (dBA), the overall size is: 1060*1060*960m m, outlet size: 670*670mm, if use it as an industrial air cooler machine, then its supporting air duct shall not exceed 25 meters in length, and the number of air outlets shall not exceed 14 at most. If this design standard is exceeded, the cooling effect will be affected to a certain extent, especially the end of the air duct is very easy to cause no cool air to blow.

Design standards for 18000air cooler:

The air supply duct of 18000 air volume air cooler can be designed to be up to 25 meters long under normal variable diameter conditions. If the installation environment does not require such a long air duct, it can be adjusted appropriately according to the on-site environment, but it cannot exceed the maximum length of 25 meters. One thing to note here is that if the design length of the air duct reaches the maximum length, then the spacing between each air outlet must be farther when designing the air outlet. For small air outlets, generally no more than 14, and for large air outlets, generally not more than 8, to ensure that the air outlet at the end of the pipe has sufficient air volume and air pressure. If the air duct length reaches the maximum length, the distance between each air outlet must be farther. If it is relatively short, then the spacing can be set smaller when designing the air outlet. If it is a direct blowing solution, recommend air outlet of 800*400mm will be sufficient. If the air duct is longer than 15 meters, it is generally necessary to start making diameter changes. Whether to make secondary or tertiary diameter changes is determined based on the specific length of the air duct. The main unit air duct with an air volume of 18,000 can be changed in diameter three times at most. The standard design of the size of the air duct diameter change is 800*400mm to 600*400mm and then to 500*400mm. Of course, corresponding adjustments can be made according to the specific situation.

industrial air cooler


Post time: Jul-16-2024